A RP-HPLC method for the simultaneous estimation of Silymarin and Thiamine in bulk and pharmaceutical forms
Murali Musuluri1*, Satyanarayana V. V. Peruri2, Haribabu Bollikolla2 and Krishnamurthy Mannam3
1R.V.R and J.C. College of Engineering, Guntur-522019, A.P., India.
2Acharya Nagarjuna University, Guntur, A.P., India.
3 P.G. Dept. of Chemistry, SVRM College, Nagaram, A.P., India.
*Corresponding Author E-mail: murali_musuluri@yahoo.com
ABSTRACT:
For the simultaneous estimation of Silymarin and Thiamine in bulk and pharmaceutical dosage forms a rapid, simple reverse phase high-performance liquid chromatographic method was developed and validated. Using Inertsil ODS C-18, 5µm column with 250 x 4.6mm internal diameter, chromatographic analysis was carried out with a mixture of methanol: acetonitrile: tetrahydrofuran in the ratio of 30:65:05 (v/v/v) as mobile phase. Different analytical parameters such as linearity, precision, accuracy, specificity, limit of detection (LOD) and limit of quantification (LOQ) were determined. The calibration curve was found to be linear for each analyte in the desired concentration range. The percentage recovery was found to be 101.17 and 99.86 for Silymarin and Thiamine respectively. It is substantiated from the LOD value of 0.5 and 0.1 ppm for Silymarin and Thiamine respectively that the proposed method is highly accurate, sensitive and precise. Hence the present method can be applied successfully for the quantification of active pharmaceutical ingredient (API) content in the combined formulations of Silymarin and Thiamine.
KEYWORDS: RPHPLC, Mobile phase, Combination drugs, Method development, Validation.
INTRODUCTION:
Silymarin is a flavonolignan that can be used as a hepatoprotective agent. Silymarin promotes liver cell protein synthesis and decreases the oxidation of glutathione. It is a powerful antioxidant believed to protect liver and brain cells from toxins. It is also a cell membrane stabiliser and permeability regulator that prevents hepatotoxic agents from entering hepatocytes. It also promotes ribosomal RNA synthesis, stimulating liver regeneration and also can be used as inhibitor of the transformation of stellate hepatocytes into myofibroblasts causing cirrhosis. Chemically silymarin is 2-(2,3-Dihydro-2-(4-hydroxy-3-methoxyphenyl)-3-(hydroxymethyl)-1,4-benzodioxin-6-yl)-2,3-dihydro-3,5,7-trihydroxy-4H-1-benzopyran-4-one. Its molecular formula is C25H22O10 and molecular weight is 482.4.
Fig 1: Structure of silymarin
Thiamine also called vitamin B1 is required for the health of the nervous system and is used in the biosynthesis of a number of cell constituents, including the neurotransmitter acetylcholine and gamma-aminobutyric acid. It is used in the manufacture of hydrochloric acid and therefore plays a part in digestion. Deficiency of it leads to beriberi and inflammation of the nerves outside the brain (peripheral neuritis) associated with pregnancy or with vitamin-deficiency disease called pellagra. Thiamine is 2-[3-[(4-Amino-2-methyl-pyrimidin-5-yl) methyl]-4-methyl-thiazol-5-yl] ethanol. Its molecular formula is C12H17N4OS and molecular weight is 300.8
Fig 2: Structure of thiamine
Silymarin and vitamin B therapy can be used to reduce bothersome symptoms of viral hepatitis and improve quality of life and overall well-being. Literature study revealed that there are liquid chromatographic1-16, colorimetric17-18, spectrophotometric19-20 and other methods available for determination of silymarin components or thiamine individually or with other combinations. But there are no RP-HPLC methods available for the simultaneous determination of silymarin and thiamine alone.
Hence we report a new simple, rapid and precise RP-HPLC method for the simultaneous determination of silymarin and thiamine in combination dosage form.
MATERIALS AND METHODS:
Chemicals and Reagents
HPLC grades of water, acetonitrile, methanol and tetrahydrofuran were purchased from Merck Specialties Private Limited, Mumbai, India. The pure standard reference drugs, Silymarin and Thiamine, were purchased from Reddy’s Laboratory, Hyderabad and pharmaceutical formulation used for this study was procured from the local market.
Instrumentation
A Denver analytical Balance was used to weigh the drug and then for wavelength checking UV-2306 spectrophotometer was used. An isocratic PEAK HPLC instrument with Zodiac C18 column (250 mm x 4.6 mm, 5μ) was used to develop a High Pressure Liquid Chromatographic method for the quantitative estimation of Silymarin and Thiamine. The instrument was equipped with a LC 20AT pump for solvent delivery and variable wavelength programmable LC–7000 UV detector. A 20μL Rheodyne inject port was used for injecting the samples. Data was analyzed by using PEAK software.
Experimental Condition
Flow rate of the mobile phase was changed from 0.5 – 1.5 ml/min for detecting optimum separation as the usage of solvents need to be reduced by minimum flow rate as well as minimum run time. Based on this it was found from the experiments that 0.8 ml/min flow rate was ideal for the successful elution of the analyte. The HPLC system was hence operated using an isocratic mode at this flow rate of 0.8 ml/min at 25 ± 2ºc. For analysis the most suitable wavelength of 220 nm and a mobile phase consisting of methanol, acetonitrile and tetrahydrofuran in the ratio of 30:65:05 was finally selected.
Preparation of Mobile Phase
For the preparation of mobile phase suitable for the present estimation methanol, acetonitrile and tetrahydrofuran of HPLC grade were mixed, filtered and degassed in such a way that the final volume consisted of these in the ratio 30:65:05 respectively with a pH value of 5.4.
Preparation of mixed standard solution
Methanol was selected as the solvent for preparation of the stock solutions of Silymarin and Thiamine (1mg/ml). Aliquots of mixed standard solutions of Silymarin and Thiamine were diluted in methanol to get a final concentration of 100, 90,80,70,60 and 50 ppm.
Preparation of sample solution of pharmaceutical formulation
Pharmaceutical form containing 35 mg of Silymarin and 1.5 mg of Thiamine was weighed and dissolved in 25 ml of methanol and sonicated for 15 min. Using methanol the volume was made up to 50 ml and filtered through 0.45μ membrane filter. The final mixed sample solution corresponding to 75 ppm of Silymarin and 75 ppm of Thiamine was prepared.
Recording of chromatograms
After stabilization of the base line with the optimized chromatographic conditions, standard solutions containing 100-50 ppm of Silymarin and Thiamine were injected and the corresponding chromatograms were recorded. Retention time of Silymarin and Thiamine were consequently found. Likewise for sample solution chromatograms were recorded. Calibration curves were plotted using peak area retentions of standard drug peaks against concentration of corresponding standard solutions.
RESULTS AND DISCUSSION:
Method validation
The method was validated by determining linearity, precision, accuracy, specificity, ruggedness and robustness by analyzing 100-50 ppm of both Silymarin and Thiamine.
TABLE 1: OPTIMIZED CHROMATOGRAPHIC CONDITIONS FOR ESTIMATION OF SILYMARIN AND THIAMINE
|
Mobile phase |
Methanol :Acetonitrile : THF 30:65:05(v/v/v) |
|
Pump mode |
Isocratic |
|
A.P.I Conc |
Silymarin - 70 ppm, Thiamine- 70 ppm |
|
pH |
5.4 |
|
Diluents |
Mobile phase |
|
Column |
C18 column (250 X 4.6 mm, 5μ) |
|
Column Temp |
Ambient |
|
Wavelength |
220 nm |
|
Injection Volume |
20 μL |
|
Flow rate |
0.8 ml/min |
|
Run time |
8 minutes |
|
Retention Time |
Silymarin - 2.3 min, Thiamine - 3.8 min |
|
Theoretical plates |
Silymarin - 7248, Thiamine - 30992 |
|
Tailing factor |
Silymarin- 0.07, Thiamine - 1.92 |
Linearity
Linearity of the proposed method was done by analyzing six solutions in the range of 50-100 ppm for both Silymarin and Thiamine. The calibration curve was drawn by using concentration of the analytes versus peak area. Good linearity was observed over the above range for both Silymarin and Thiamine. From the linear regression analysis, the correlation coefficient was calculated and found to be 0.998 in case of both the analytes indicating that there exists a good linear relationship between concentration of drugs and the peak area. The linear regression analysis data is given in Table 2.
Fig 3: Calibration plot for silymarin
Fig 4: Calibration plot for thiamine
TABLE 2: REGRESSION ANALYSIS OF THE CALIBRATION CURVE
|
Parameters |
Silymarin |
Thiamine |
|
Calibration range (ppm) |
50-100 ppm |
50-100 ppm |
|
Slope |
2967.6 |
2687 |
|
Intercept |
-5255 |
-3424.9 |
|
Correlation coefficient (r2) |
0.998 |
0.998 |
Precision
The precision of an analytical method is the closeness of replicate results obtained from analysis of the same homogeneous sample. The precision of the assay was studied with respect to both repeatability and intermediate precision in accordance with ICH recommendations. Repeatability was calculated from six replicate injections of freshly prepared Silymarin and Thiamine combined test solution in the same equipment at a concentration value of 70 ppm on the same day. The experiment was repeated by assaying freshly prepared solution at the same concentration additionally on two consecutive days to determine intermediate precision. Peak areas of the drugs were determined and precision as % RSD was reported.
TABLE 3: PRECISION FOR THIAMINE, SILYMARIN
|
Peak Area of Silymarin |
Peak Area of Thiamine |
RSD (Acceptance criteria ≤ 2.0%) |
|
200429 |
178089 |
Silymarin-0.135
|
|
200803 |
177316 |
|
|
198625 |
178916 |
|
|
198873 |
177930 |
Thiamine-0.44 |
|
198485 |
178084 |
|
|
198295 |
179507 |
Fig 5: Typical chromatogram of standard silymarin and thiamine mixture
Recovery
A fixed amount of pre analyzed sample was taken and standard drug was added at 50%, 100% and 150% levels to study the accuracy and reproducibility of the proposed method. Each level was repeated three times. The contents of Silymarin and Thiamine per tablet found by proposed method are shown in Table 4 and the lower values of RSD of assay indicate the method is accurate. The mean recoveries of Silymarin and Thiamine in range of 98.93% and 99.13% indicate no interference from excipients.
Specificity
Specificity and selectivity of the proposed method were checked by making a synthetic mixture of both the analytes with commonly occurring excipients that are found in most tablet formulations and then measuring the percentage recovery of each component along with chromatographic parameters under normal conditions. The results showed no interference from the excipients or impurities.
Limit of detection (LOD) and limit of quantification (LOQ)
From standard deviation of y-intercept of regression line and the slope LOD and LOQ were determined as per ICH guidelines and are shown in Table 4.
TABLE 4: SYSTEM SUITABILITY AND VALIDATION PARAMETERS
|
Parameters |
Silymarin |
Thiamine |
|
Theoretical plates (N) |
7248 |
30992 |
|
Retention time (min) |
2.3 |
3.8 |
|
Tailing factor |
0.07 |
1.92 |
|
LOD (ppm) |
0.5 |
0.3 |
|
LOQ (ppm) |
0.5 |
0.1 |
|
Accuracy (%) |
98.93 |
99.13 |
|
R.S.D. (%) |
0.135 |
0.44 |
TABLE 5: FORMULATION: LIVBEL
|
S.NO |
Drug |
Dosage |
Sample Conc. |
Area |
Amount of drug estimated |
% of drug estimated |
|
1 |
Silymarin |
35mg |
75 ppm |
218400 |
74.497 ppm |
99.33 |
|
2 |
Thiamine |
1.5 mg |
75 ppm |
199039 |
75.457 ppm |
100.61 |
Analysis of marketed formulations
The validated HPLC method was adopted for the quantification of Silymarin and Thiamine in their combined pharmaceutical dosage form and the typical chromatograms of the formulation are shown in Fig 6. The results of analysis are given in Table 5. The contents of the pharmaceutical dosage form were found to be in the range of 100±2% with RSD less than 2% which indicate suitability for routine analysis of Silymarin and Thiamine in pharmaceutical dosage form.
Fig 6: Chromatogram of pharmaceutical dosage form
CONCLUSION:
The new simple, rapid and precise RP-HPLC method proposed can be used for the simultaneous determination of silymarin and thiamine in combination pharmaceutical dosage form.
ACKNOWLEDGEMENT:
The authors are very much grateful to the Management of R.V.R and J.C College of Engineering and Acharya Nagarjuna University, Guntur, India for their moral support and encouragement shown in carrying out this work.
REFERENCES:
1. Ghada MH et al. Validated Optimized Method for Simultaneous Analysis of Active Silymarin Components and dimethyl 4, 4’-dimethoxy-5, 6, 5’, 6’-dimethylene dioxybiphenyl-2, 2’-dicarboxylate in a Pharmaceutical Preparation by Use of a Monolithic Silica C18 Column. Chromatographia 70; 2009: 217-21.
2. Xin Ru Li et al. Determination of silymarin in microemulsion by RP-HPLC. Journal of Chinese Pharmaceutical Sciences. 18; 2009: 190–2.
3. James I. Lee et al. Analysis and comparison of active constituents in commercial standardized silymarin extracts by liquid chromatography-electrospray ionization mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 845; 2007: 95–103.
4. Tian-ming Ding et al. Determination of active component in silymarin by RP-LC and LC/MS. J Pharm Biomed Anal. 26; 2001: 155-61.
5. Zhisheng CAO et al. Determination of Six Isomers of Silibin in Silymarin Capsules by HPLC. Traditional Chinese Drug Research and Clinical Pharmacology. 2006:03.
6. Peer Basha D et al. HPLC Method development for Simultaneous Estimation of Pyridoxine, Thiamine, Paracetamol and Ibuprofen in Tablets. J Pharm Res. 4; 2011: 1584-5.
7. Yantih N et al. Validation of HPLC method for Determination of Thiamine Hydrochloride, Riboflavin, Nicotinamide and Pyridoxine Hydrochloride in Syrup Preparation. Canadian Journal on Scientific and Industrial Research. 2; 2011: 269.
8. Jin Tan et al. Determination of thiamine (vitamin B1) in pharmaceutical tablets and human urine by titania-based ligand-exchange hydrophilic interaction chromatography. Anal. Methods. 3; 2011: 1568-73.
9. Thomas S et al. HPLC Method development for Simultaneous Estimation of Pyridoxine, Thiamine, Paracetamol and Ibuprofen in Tablets. Indian J.O. Chem. Technol. 15; 2008: 598-603.
10. Yantih N et al. Determination of Seven Water-Soluble Vitamins in Tablet Simultaneously by Reversed-Phase High Performance Liquid Chromatography. The International Seminar on Pharmaceutics, Institute Technology Bandung, Indonesia: 2007.
11. Amidzic R et al. RP-HPLC Determination of vitamin B1, B3, B6, folic acid, and B12 in multivitamin tablets. J. Serb. Chem. Soc. 70; 2005: 1229-35.
12. Marcin Leszek Marsza et al. High-performance liquid chromatography method for the simultaneous determination of thiamine hydrochloride, pyridoxine hydrochloride and cyanocobalamin in pharmaceutical formulations using coulometric electrochemical and ultraviolet detection. J Chromatogr A. 1094; 2005: 91–8.
13. Pavlos FC et al. Development of a validated HPLC method for the determination of B- complex vitamins in pharmaceuticals and biological fluids after solid phase extraction. J Sep Sci. 27; 2004: 1181–8.
14. Li K. Simultaneous determination of nicotinamide, pyridoxine hydrochloride, thiamine mononitrate and riboflavin in multivitamin with minerals tablets by reversed-phase ion-pair high performance liquid chromatography. Biomed Chromatogr. 16; 2002: 504-7.
15. Din E et al. A comparison of matrix resolution method, ratio spectra derivative spectrophotometry and HPLC method for the determination of thiamine HCl and pyridoxine HCl in pharmaceutical preparation. J Pharm Biomed Anal. 22; 2000: 915-23.
16. Khor Swan Choo, Tee E Siong. Development of a HPLC method for the simultaneous determination of several B-vitamins and ascorbic acid. Mal J Nutr. 2; 1996: 49-65.
17. Zarapkar SS et al, Colorimetric estimation of silymarin in pharmaceutical dosage form. Indian Drug. 37; 2000: 133-4.
18. Prasad PSS et al. Colorimetric Determination of Thiamine Hydrochloride Using Alzarin Briliant Violet R. Indian J Pharm Sci. 59; 1997: 194-6.
19. Rajasekaran A et al.. Spectrophotometric Determination of Silymarin. Indian J Pharm Sci. 59; 1997: 230-1.
20. Devyani D and Vyas SP. Simultaneous Spectrophotometric Estimation of Lamivudine and Silymarin in Mixture. International Journal of Pharmacy and Pharmaceutical Sciences. 1; 2009: 107-11.
Received on 06.06.2012 Modified on 04.07.2012
Accepted on 04.10.2012 © AJRC All right reserved
Asian J. Research Chem. 5(12): Dec., 2012; Page 1440-1443